 | | Visual tool for creating full screen user interface designs. | ENLARGE IMAGE |
 | | Measurement device configuration and communications diagnostics. | ENLARGE IMAGE |
NWA Quality Monitor provides SQC charts for all types of measurements—whether variable or attribute—in one package. The software offers the same chart-generating capabilities as our award-winning NWA Quality Analyst, producing all standard SQC/SPC charts and reports. Variable Control Charts- X-bar
- Range
- Standard Deviation
- Individual Measurements
- Moving Average
| - Median
- Median/Individual Measurements
- Cumulative Sum (CUSUM)
- Exponentially Weighted Moving Average (EWMA)
|
Attribute Control Charts- Percent Defective (p)
- Number Defective (np)
- Defects (c)
- Defects per Unit (u)
Short Run Analysis (for all charts)Pareto AnalysisProcess Capability AnalysisSelect one of eight distribution types: - Normal
- Skewness and Kurtosis Adjusted (Johnson)
- Two Parameter Log normal
- Three Parameter Log normal
- Truncated Normal
- Folded Normal
- Weibull
- Rayleigh
User Interface can be composed of any number and combination of components - Input Box
- Key entry
- Drop-down selection list
- Measurement device input
- Display Box
- Calculations
- Informational data
- Tabulate Box - simplifies defect category entry
- Input Prompt - specific to each Input Box
- Label Text - full font and color control
- Picture - supports BMP, GIF, JPG, and other formats
- Command Bar - dockable groups of command buttons
- Pop-up Menu - cascading groups of command buttons
- Action Button - individual command button
- Alarm Indicators - alarms linked to each input and display box
- Alarm List - displays current alarms
- "Quick View" - tabular display of previously collected data
Input source and management features - Source
- Keyboard entry
- Read from measurement device
- Read from barcode
- Read from text file
- Calculation result from defined formula
- Constant value
- Incrementing or sequence count
- Default to previous value
- System date - system clock
- System time - system clock
- Upper and Lower Bound limits
- Allow/Prevent modification of existing data
- Input Mask for key, device, and calculation input
- Field-specific prompt text
- Field-specific help reference
Command Bar, Pop-up Menu, and Action Button options - Command bars dock to any margin
- Pop-up menus cascade to 10 levels
- Button text includes full font and color control
- Button definition includes short-cut (function) keys
- Command Actions
- Display Chart - display SPC charts
- Print Chart - print SPC charts
- Help - display field-specific help
- Alarms - display alarm lists
- Run - start Quality Analyst automation script
- Send - send pre-defined commands to devices
- Launch - start other Windows applications
- Archive - manually start data archive
Complete SOP support on the plant floor - Context sensitive help for each input field
- Full font and color control
- Embedded graphics and pictures
- Includes built-in Help file editor
- Reads RTF file format from word processors and editors
Visual and audible alarming on specifications and SPC limits - Alarm Types
- Specifications
- SPC Limits - control, warning, and rule violations
- Fixed Limits
- Alarm Indicators
- Separate indicators for each alarm type
- Specific to each Input and Display field
- Alarm Lists
- Fully definable text for each alarm type
- Pop-up or continuous display
- Includes complete alarm history for each data record
- Alarm Actions
- Add message to alarm list
- System beep
- Assign text comment to data field
- Play .WAV files
- Send alarm list by email at record completion
Real-time data collection from measurement devices - Interfaces through standard RS-232 (serial) ports
- Simple point-and-click device definition
- Interfaces with common measurement devices
- Scales
- Gages
- Multiplexers
- Special Purpose
- Includes extensive library of predefined devices
- Device configuration and troubleshooting tool
- Troubleshoot communications problems
- Test input devices
- Interface with text files
- Link multiple NWA Quality Monitor® workstations for multistep manufacturing processes
- Uses NWA Quality Analyst® Data Sets
- Allows up to 200 characteristics per Data Set (includes any combination of variable, attribute, or descriptive data)
- Automatically writes to ODBC-compliant databases (e.g., SQL Server, Oracle, MS Access, etc.)
- Reads specifications and descriptive data from ODBC-compliant databases
- NWA Quality Analyst required for Data Set definition and SPC chart configuration
- NWA Quality Monitor Designer (screen design, device configuration, help) to configure plant-floor workstations
- NWA Quality Monitor Runtime installs on each plant-floor workstation
- Windows* 95, 98, Me, NT4, 2000, XP, or Server 2003
- Any PC-based LAN (Windows* NT*, Novell*, etc.)
Recommended minimum systems:- Quality Monitor Designer:
266 MHz Pentium 32 MB RAM - Quality Monitor Plant-floor Workstations:
120 MHz Pentium 16 MB RAM Slower systems may be used for plant-floor workstations, depending on size and complexity of data input screens.
NWA Quality Analyst and NWA Quality Monitor are trademarks or registered trademarks of Northwest Analytical. * All other company and product names may be trademarks or registered trademarks of those respective companies. All specifications within this document are subject to change without notice.
|